Menu

Multivariable Process Control-SB-MPC-6

Product Description: This system will include an Advanced field calibrator and communicator, Internal Pressure Module, Pressure/vacuum pump kit, Field Temperature Block, Calibration Software for Total Pressure and temperature Calibration report generation, and Unit Under Calibration Setup.

Learning Facilities:
Pressure Generation, Measurement and calibration of pressure measuring devices.
Temperature Generation, Measurement and calibration of Temperature measuring devices.
HART communication with supported devices.
Make proper calibration certificate and paperless calibration from calibration software.
Generate loop current, Voltages, RTD, TC, Hartz Signals.

ADVANCED FIELD CALIBRATOR AND COMMUNICATOR:
This is a Compact, Lightweight Portable multifunction calibrator for measure, source and simulate functions of Electrical, like DC current (mA), DC Voltage (VDC), DC mV, Resistance (ohm), Frequency (Hz), RTDs (Pt-50, Pt- 100, Pt-200, etc.) and Thermocouples (type K, N, S, R, T, B, J, etc.)
General Specification is given below:
Pressure measurement – different option available for MC6, (Total 4 internal pressure modules and external pressure module connection is possible with MC6).
Voltage measurement (±1 V and ?1 … 60 VDC).
Current measurement (±100 mA) (internal or external supply).
Frequency measurement (0 … 50 kHz).
Pulse counting (0 … 10 Mpulse).
Switch state sensing (dry/wet switch).
Built-in 24 VDC loop supply (low impedance, HART impedance).
Voltage generation. (±1 V and ?3 … 24 VDC).
Current generation (0 … 55 mA) (active/passive, i.e. Internal or external supply).
Resistance measurement, two simultaneous channels (0 … 4 k?).
Resistance simulation (0 … 4 k?).
RTD measurement, two simultaneous channels.
RTD simulation.
TC measurement, two simultaneous channels (universal connector/mini-plug).
TC simulation.
Frequency generation (0 … 50 kHz).
Pulse queue generation (0 … 10 Mpulse).
Documenting Calibrator Feature.
HART Communication Feature.
FOUNDATION Fieldbus Communication Feature.
Profibus PA Communication Feature
Detailed Specification:
Display: 5.7” Diagonal 640 x 480 TFT LCD.
Touch Panel: 5-Wire Resistive Touch Screen.
Keyboard: Membrane Keyboard.
Battery Type: Rechargeable Lithium-Ion polymer, 4200 mAh, 11.1V.
Battery operation: 10 ... 16 hours.
Charger Supply: 100…240 VAC, 50-60 Hz.
Operating Temp: -10…45°C (14…113°F).
Case protection: IP65.
Storage Temp: -20 to 60°C (-4 to 113°F).
Humidity: 0 to 80% R.H. noncondensing.
Max. Input Voltage: 30VAC, 60VDC.
Weight: 1.5-2.0 Kg..
Dimensions: 200mm D x 230mm W x 70mm H.
Warm up time: Specification valid after a 5-minute warm up period.
Safety: Directive 2006/95/EC, EN 61010-1:2001.
EMC: Directive: 2004/108/EC, EN 61326-1:2006.
Ingress protection IP65.
RoHS compliance ROHS II Directive 2011/65/EU, EN IEC 63000:2018.
Drop: IEC 60068-2-32. 1 meter (3.28 ft).
Vibration: IEC 60068-2-64. Random, 2 g, 5-500 Hz.
Max altitude: 3,000 m (9,842 ft).
Pressure Measurement – INTERNAL MODULE.
Range: –1 to 20 bar.
Resolution: 0,0001.
Accuracy: 0.01% FS + 0.025% RDG.
1 Year Uncertainty: 0.01 % FS + 0.025% RDG (±).
INBUILT HART COMMUNICATION MODULE:
The HART communication includes the latest HART DD Library published by HART Communication Foundation (HCF) in February 2012. Totally 740 devices with 1220 DD’s are included in the package.
STANDARD ACCESSORIES:
Accredited calibration certificate.
User guide.
Computer cable (USB).
Battery charger / eliminator.
Internal LiPO battery pack.
Test leads and clips.
Soft carrying case

HANDHELD PNEUMATIC ALIBRATION PUMP:
The PGC calibration pump -0.95 ... 35 bar (-13.7 … 510 psi) is a hand-operated calibration pump that can be used to generate pressure and vacuum (pressure media: air). When using the pressure/vacuum selector you can quickly choose between generating pressure or vacuum. The PGC pump also provides the means to accurately fine tune the generated pressure.
The pressure connection consists of pressure port with G1/8" female thread and a pre-installed Bx G1/8" male fitting for 40 bar (600 psi) hoses (7113270 Pressure fitting Bx G1/8" male to G1/8" male).
Dimensions: 220 x 120 x 65 mm.
Weight: 820 g.
The standard delivery includes: PGC pump. user manual
DRY BLOCK TEMPERATURE BATH
FIELD TEMPAERTURE CALIBRATOR
The FB is an easily portable unit that also provides excellent calibration accuracy. The display accuracy is up to ±0.2 °C and its control technology provides great stability up to ±0.01 °C. The dual zone-controlled block provides excellent axial uniformity up to ±0.04 °C and radial uniformity up to ±0.01 °C.
Temperature range at 23 °C –25 °C to 150 °C (–13 °F to 302 °F).
Display accuracy: ±0.2 °C Full range. Stability: ±0.01 °C Full range.
Axial uniformity at 40 mm ±0.05 °C Full range.
Radial uniformity: ±0.01 °C
Full range 23 min: 23 °C to 150 °C. 25 min: –25 °C to 150 °C. 5 min: 33 °C to 350 °C 15 min: 50 °C to 660 °C.
Cooling time 15 min: 23 °C to –25 °C. Resolution 0.01 °C / °F. Display LCD, °C or °F user-selectable. Size (H x W x D) 290 mm x 185 mm x 295 mm.
Weight 8.16 kg.
Power requirements 230 V (±10%) 50/60 Hz, 575 W.
Computer interface RS-232.
Calibration Accredited calibration certificate provided.
Environmental operating conditions 0 °C to 50 °C, 0% to 90% RH (non-condensing).
Specifications valid in environmental conditions 13 °C…33 °C.