Specification:
Power Supply is a state-of-the-art solid-state regulated power supply for operating low power Klystrons. It incorporates a number of proprietary. Regulated Beam Supply and Repeller Supply voltages. LED Digital meter for Beam voltage current and Repeller voltage. Compact and Reliable. Modular construction for easy maintenance. In addition to AM and FM modulation of beam current a provision for external modulation is provided.
Beam Supply: Voltage : Variable 240 - 420 VDC.
Current: 50 mA. Ripple: < 4 m Vrms (ON Load). Repeller Supply : Variable -18 V to -270 V DC (ON Load) Filament Supply : Adjustable 6.3 VDC. Over-Load trip current: 65 mA.
Digital Panel meter : 2 V Modulation: AM (Square) Frequency Range : 500 - 2000 Hz 0 - 110 Display: 16 × 2 Characters LCD. Sensitivity: 0.1 mV for 200 W input impedance. Noise Level: Less than 0.02 mV. Range: 0 - 60 dB in 10 dB steps. Input : Un-biased low and high impedance biased crystal ( 200 W and 200 K). Display Select: SWR 1 - 9 dB 0 - 10. Modes: Normal Audio PC-Interface. Gain Control: Adjusts the reference level variable range 0 -10 dB approx. Input Connector: BNC (F). Input Frequency: 1000 Hz ± 10%. Power Supply: 220 V± 10% 50Hz. Solid Directional Cell: These are used to measure dielectric constant of any solid material these consists of a cavity for keeping the sample and micrometer to read the position of sample. Frequency: 8.2-12.4GHz Max. length of cell: 100mm.
Plunger movement: 25mm. Cross Directional Coupler: Cross Directional Coupler consists of two waveguide sectional joint at (90°) with the coupling element mounted into the common broad wall. Coupling (dB): 20dB Coupling accuracy: ±1dB. E-Plane Tee: Frequency: 8.2-12.4GHz Max. length of cell: 200mm.
Plunger movement: 65mm.
Micrometer Type Frequency Meter: Micrometer type frequency meters are consisting of a microwave cavity with plunger and a section of waveguide. It consists of a micrometer to measure its position for measuring frequency. Frequency: 8.2-12.4GHz Max. VSWR: 1.15 Calibration accuracy: ±2%.
Calibration increment: 10 MHz Waveguide Antennas: Frequency: 8.2-12.4GHz Antenna type: Pyramidical. Gain: 16. Multi-hole Directional Coupler: Directional coupler is designed to measure incident and reflected power values long scale length and numbered calibration marks provide high. resolution which is particularly useful when measuring frequency. difference of small frequency change. . Each adaptor covers the 50% of the waveguide. Frequency: 8.2-12.4GHz Connector: N Type. Max. VSWR: 1.12 at 10.5 GHz. Return loss: -24.5 at 10.5GHz. Tunable Probe: Tunable probes are very useful devices to measure the SWR and Impedances. Tunable probe is consisting of aTo be Continue crystal detector and a small wire antenna in coaxial housing. Its depth of penetration into the slotted section is variable. Frequency: 8.2-12.4GHz Detector: IN23. Tunable type. Klystron Mount: Klystron mounts are used to transmit microwave. Accessories: Power Cable: 01 nos.
Connecting Wire.
User Manual.